DC46136V20A
DC=Direct Current (Polarity Sensitive)
461 = MIL-STD-461 compliant
36V = 0-36V operating range
20A = 20A operating current
Operating Specifications
Sensitive: Yes, this device will be damaged by reverse polarity
Nominal Operating Voltage: 0-36VDC
Maximum Input Voltage: 100VDC
Current: 0-20A
Temperature: -40C to 55C
In an ambient temperature, To, higher than 55C, maximum operating current, Io is
Io = Ir * Sqrt[(85-Tq)/55]
Vibration: Vibration, MIL-STD-810F, Method 514.6, Procedure I, 5.85 GRMS, 5-500Hz,
75 min/axis
Humidity: MIL-STD-810F, Method 507.4, 21 days @ 40C, 95% RH
Shock: MIL-S-901D, Grade A, Class 2, Type B
Storage Temperature: MIL-STD-810F, Method 501.5, Procedure I/II, -55C to 85C
HiPot: Line to ground: 100V
Line to line: 100V |